Storage Viewer for Capacity Database Views > aps_v_vnx_backend_storage_sys
  
Version 10.0.01
aps_v_vnx_backend_storage_sys
The aps_v_vnx_backend_storage_sys contains a single row for each Celerra backend system.
Table 4.141 aps_v_vnx_backend_storage_sys
Column Name
Data Type
Description
backend_ss_uid
STRING
Specifies the CLARiiON UID identifier
cache_kb
NUMBER
Returns the size of the cache in this storage system
component_type
STRING
Returns the type of component. In this case, it is storage System
disk_count
NUMBER
Returns the number of physical disk devices in this storage system
frontend_system_name
STRING
System name
high_watermark_pct
NUMBER
Specifies the percentage of dirty pages required to start a cache flush
is_local
CHAR
Indicates that if false then the storage is a remote storage system
last_updated
DATE
Last updated date
low_watermark_pct
NUMBER
Specifies the percentage of dirty pages required to stop a cache flush
max_severity
STRING
Returns the maximum (worst) severity among all problems that the task or query experienced during the run
nbr_of_luns
NUMBER
Number of logical units
nbr_of_raid_groups
NUMBER
Specifies the number of RAID groups
nbr_of_storage_groups
NUMBER
Specifies the number of storage groups
nbr_of_visible_luns
NUMBER
Number of visible LUNs
serial_nbr
STRING
Returns the EMC Serial number assigned to this storage System
snapshot_time_sec
NUMBER
Specifies the GMT time in seconds when this snapshot of data was taken
software_version
STRING
Returns the software version of this system software
ss_model
STRING
Returns EMC storage model
storage_obj_id
STRING
Specifies the ID of the storage system
system_name
STRING
Returns the Celerra name of this storage system
up_time
STRING
Returns the time passed since Symmetrix bootup
vnx_storage_system_id
NUMBER
Internal key, foreign key to the aps_vnx_storage_system.vnx_storage_system_id