Storage Viewer for Capacity Database Views > aps_v_vpl_director
  
Version 10.0.01
aps_v_vpl_director
The aps_v_vpl_director contain a single row for each director.
Table 4.191 aps_v_vpl_director
Column Name
Data Type
Description
application_status
STRING
Current status of this application instance.
array_name
STRING
Array name
cimom
STRING
The low-level SMI-S interface to the storage firmware.
communication_status
STRING
The connectivity status between this director instance and the firmware.
creation_date
DATE
The date and time the VPLEX director data was created in the database.
description
STRING
Describes the director’s system type.
director_count
NUMBER
The number of directors this director expects at its cluster.
director_family
STRING
The hardware family to which this director belongs.
director_id
STRING
The system-generated unique identifier for this director.
director_name
STRING
Name of the VPLEX director.
director_type
STRING
The type of VPLEX director.
engine_name
STRING
Name of the VPLEX engine.
failover_hostname
STRING
If available, the hostname of the failover connection.
failover_port
NUMBER
If available, the port of the failover connection.
firmware_name
STRING
Firmware name.
firmware_uid
STRING
Unique ID for the application instance.
firmware_uptime
STRING
Uptime for the application instance.
firmware_version
STRING
The version information of the application.
health_indications
STRING
Indicates the reasons that a health-state that is not OK.
health_state
STRING
Indicates the overall health of the director.
hostname
STRING
Host name or IP address of the remote system.
is_auto_boot
STRING
Indicates whether the application is automatically booted on power up.
is_auto_restart
STRING
Indicates whether the application is automatically rebooted after a failure.
is_commissioned
STRING
Indicates if the director is commissioned: true or false.
is_temp_threshold_exceeded
STRING
Indicates if the temperature of the director has exceeded the threshold.
is_voltage_threshold_exceeded
STRING
Indicates if the voltage of the director has exceeded the threshold or not.
last_updated
DATE
The date and time the VPLEX director data was last updated in the database.
markerled
STRING
The current status of the marker LED of the director.
operational_status
STRING
Indicates the current status of the director.
part_number
STRING
The EMC part number of this director component.
port
NUMBER
Remote system port used for communication.
revision_number
STRING
The EMC revision number of this director component.
run_level
NUMBER
The current firmware run level. A higher run level enables more features.
serial_number
STRING
The EMC serial number of this component.
sp_id
STRING
The SP ID of the director.
vpl_director_id
NUMBER
Director ID, for internal use by the database.
vpl_engine_id
NUMBER
Engine ID, for internal use by the database.
vpl_storage_system_id
NUMBER
Storage system ID, for internal use by the database.
vplex_status
STRING
The state of the VPLEX splitter on this director.
xml_trace_enabled
STRING
For future use.