Column Name | Data Type | Description |
array_id | STRING | Array ID |
arsite_id | STRING | Array site ID |
da_pair | STRING | Device adapter pair ID that is associated with the specified device adapter |
data_state | STRING | Current data state Normal - The array is in the Normal data state if none of the other data states applies. This status applies if the array is unassigned. Degraded - The array is in the Degraded data state if both of the following conditions exist: The Read-only, Failed, Repairing, or Inaccessible data states do not apply.One or more redundancy groups are rebuilding (that is, there is a DDM with a rebuilding state in the array). |
ddm_capacity_gb | NUMBER | Minimum disk capacity (10^9B) of the storage devices (DDMs) in the designated array in gigabytes |
ddm_capacity_kb | NUMBER | Minimum disk capacity (10^9B) of the storage devices (DDMs) in the designated array in kilobytes |
ddm_rpm | NUMBER | Minimum disk rpm of the DDMs in the designated array |
disk_class | STRING | Disk class is either high speed fibre-channel disk drives or near-line disk drives ENT - Specifies enterprise and represents high speed fibre-channel disk drives NL - Specifies near-line and represents ATA (FATA) disk drives |
disk_interface_rate | NUMBER | Minimum disk interface rate of the disks in the designated array |
disk_interface_type | STRING | Disk interface type of the DDMs in the designated array |
ibm_array_id | NUMBER | Foreign key to array details |
ibm_array_site_id | NUMBER | Foreign key to array site details |
ibm_device_adapter_id | NUMBER | Foreign key to device adapter details |
ibm_storage_system_id | NUMBER | Foreign key to IBM storage system details |
last_update | DATE | last updated date |
raid_type | STRING | Type of RAID array (5 or 10) and the array configuration (for example, 6+P) |
serial_nbr | STRING | Unique internal identifier for the data space of the designated array |
state | STRING | Assigned - The array is assigned to a rank. Unassigned - The array is not assigned to a rank and all of the storage devices that are indicated by the disk serial numbers attribute are in the normal state. Unavailable - The array is not assigned to a rank and one or more of the disk drive modules (DDMs) that are indicated by the disk serial numbers attribute are not in the normal state. Read Only -The array is in the Read-only data state if all of the following conditions exist: The Failed, Repairing, and Inaccessible data states do not apply. One or more DDMs have failed. There are insufficient spares to support all rebuild operations. Continued write operation without redundancy could result in data loss. Failed - The array is in the Failed data state if all of the following conditions exist: The Repairing and Inaccessible data states do not apply. Two or more DDMs in the array have failed. There are insufficient DDMs left in the array to rebuild the data that was lost on the failing storage devices. Repairing - The array is in the Repairing data state if all of the following conditions exist: The Inaccessible data state does not apply. The array has previously entered the failed state. The repair array function has been accepted. The repair array function has not completed. Inaccessible - The array is in the Inaccessible data state if the storage unit cannot access a set of storage devices that are sufficient to access all the data on the array. |
system_name | STRING | name assigned to the storage unit |